# A mixture of water and urea
#

# All the atoms from different molecules will be separated at least 2.0
# Angstroms in the solution.

tolerance 2.0

# The file type of the input and output files is PDB

filetype pdb

# The name of the output file

output mixture.pdb

# To write only the initial placement of the molecules to the output file,
# without packing them (to check the constraints), uncomment the line below.

# check_initial_placement

# The periodic box: from the origin to x, y and z = 40. 40. 40., a cube of
# side 40. The molecules are packed in it, and they are kept 2.0 Angstroms
# apart also from the periodic images of the other molecules.

pbc 40. 40. 40.

# 1000 water molecules and 400 urea molecules. The periodic box confines
# them: no constraint is needed.

structure water.pdb
  number 1000
end structure

structure urea.pdb
  number 400
end structure